04

In primary circuit of the power supply , a protected fuse is inserted. Only internal fault of the power supply 
will cause the fuse blown. Any overload or short circuit at DC output will keep from fuse brown or fire hazard.

4.1 Input Protection

The +5V/+12V/+3.3V DC output are protected against the under voltage condition . range value can't 
be exceed 3.3~3.7V at 5V terminal and 8.5~9.5V at 12V, 2.0~2.4V at 3.3V.

4.2 Output Protection

4.2.1 Under voltage protection

The +12V/ DC output are protected against the over voltage condition . Maximum value can't be over 
15.5V at 12V.

4.2.2 Over Voltage Protection

The power supply can be used electronic circuit to limit the output current against exceeding 10%-60% 
of surge output power or protected against excessive power delivery since short circuit of any output 
or over total power at high line.

4.2.3 Over Power Protection

4. Protection

5.1 No Load Start

5. Start Stability

Short circuit placed on +5V,+12V,+3.3V,-12V will latch off. +5VSB will auto-recovery.

4.2.4 Short Circuit Protection

This power supply includes an over-temperature protection sensor, which can trip and shut down the 
power supply at 110

4.2.6 Over-Temperature Protection

Current protection should be designed to limit the current to operate within safe operating conditions. 
Over current protection schemes where only the voltage output that experiences the over current event 
is shut off may be adequate to maintain safe operation of the power supply and the system; however, 
damage to the motherboard or other system components may occur. The recommended over current 
protection scheme is for the power supply to latch into the shutdown state. The setting of over current 
protection for each output rail is as following.

When power is applied to ST85F-PT with no load connected or under minimum load connected, neither 
damage to power supply nor hazards to users will occur.

5.2 Cold Start

The power supply shall operate properly when first applied at normal input voltage and or so maximum 
load after 4 hours storage in 0

 environment.

4.2.5 Over-Current Protection 

6.1 Temperature and Humidity

6. Environments

6.1.1 Operating

Temperature  

0 to 40C

Relative Humidity 

20 to 90 %

o

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Stone STRIDER ST85F?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"