WARNING!
Before re-connecting the hood circuit to the mains supply and
checking the efficient function, always check that the mains
cable is correctly assembled.
Warning!
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified
persons in order to avoid hazard.
Mounting
Before beginning installation:
•
Check that the product purchased is of a suitable size for
the chosen installation area.
• Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
• Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
In the case of the presence of panels and/or walls and/or
lateral wall units check that there is sufficient space to install
the hood and that access to the command panel is easy.
To remove the hood from the wall unit,
perform the
mounting steps in reverse order.
Caution!
Use suitable cut resistant gloves.
Start detaching the hood from the double-sided adhesive that
keeps it adherent to the bottom of the wall unit (see also Fig.
4)
Therefore, use a cutter that can be slipped between the sheet
metal of the hood and the bottom of the wall unit on the right
and left sides. Fig. A
Caution
! Otherwise, if you use force during extraction, the
sheet metal of the hood could be irremediably distorted.
Operation
1 ON/OFF
motor
Pressing the button, the hood turns on at speed 1.
Pressing the button during functioning, the hood turns
OFF.
2 Speed
Increase
Pressing the button the hood passes from the OFF state
to speed 1.
Pressing the button (hood in ON state) the motor speed
is increased from speed 1 to intensive.
To each speed corresponds the ignition of the respective
led.
Speed 1 led
L1
Speed 2 led
L2
Speed 3 led
L3
Intensive Speed led
L4
(flashing)
The intensive speed is timed. The standard timing is 5’,
at the end of which the hood positions itself to speed 2.
To deactivate the function before the time expires press
key
2
, the hood positions itself to speed 1, pressing key
1
the hood will turn off.
3 ON/OFF
lights
4 Speed
timing
5 Function state indicator
Speed Timing
The timing of the speed is enabled by pressing key
4
, once
the timing expires the hood turns off.
The timing is subdivided as follows:
Speed 1 - 20 minutes (led
L1
flashing)
Speed 2 - 15 minutes (led
L2
flashing)
Speed 3 - 10 minutes (led
L3
flashing)
Intensive Speed - 5 minutes (led
L4
flashing)
During the timed functioning pressing key
1
the hood turns off,
if you press key
2
or key
4
the hood returns to the set speed.
Grease trap Signal
After 40 hours of operation the led
L5
turns on.
When such signal appears the installed grease trap needs to
be washed.
To reset the signal hold down key
1
for 3”.
Carbon filter Signal
After 160 hours of operation the led
L5
flashes.
When such signal appears the installed carbon filter must be
substituted.
To reset the signal hold down key
1
for 3”.
In the case of both filters signalling at the same time, the led
L5
will indicate the alarms alternately remaining on for 3" and
subsequently flashing 3 times.
The reset takes place by carrying out the procedure described
above 2 times.
The first time resets the grease trap signal, the second resets
the carbon filter signal.
In the standard mode the carbon filter signal is not active.
In case one uses the hood in filter version is it necessary to
enable the carbon filter signal.
Carbon filter signal activation:
Position the hood in OFF and simultaneously hold down keys
1
and
4
for 3”.
The led
L1
and
L2
will flash for 5”.
Carbon filter signal deactivation:
Position the hood in OFF and simultaneously hold down keys
1
and
4
for 3”.
The led
L1
will flash for 2”.
Характеристики