 b. 

Timer: 

the LED of the selected speed flashes to 

indicate that the timer is active. 

 

c. Grease filter saturation: 

the 

L3

 and

 L4

 LEDs flash 

alternately

 at short intervals of time. 

 

d. Activated charcoal filter saturation: 

the 

L3

 and 

L4

 

LEDs flash 

simultaneously

 at short intervals of time. 

 
Reset of the filter saturation indicator: perform

 filter 

maintenance, then press button 

2

 until the LEDs turn off. 

Note:

 The activated charcoal filter saturation is normally 

disabled and is enabled only if the hood is used in the filtering 
version (with charcoal filter installed). 
In order to activate it, proceed as follows: 

Switch off the hood

 

Keep pressed simultaneously buttons 

and 

4

, until the 

LEDs 

L1

 and 

L2

 flash briefly. 

Repeat the operation to disable; only LED 

L1

 flashes briefly. 

  

Maintenance 

 

Cleaning 

Clean using 

ONLY

 the cloth dampened with neutral liquid 

detergent. 

DO NOT CLEAN WITH TOOLS OR 

INSTRUMENTS

. Do not use abrasive products. 

DO NOT USE 

ALCOHOL! 

 

Grease filter 

Fig. 3-12 
Traps cooking grease particles. 

 

The grease filter

 must be cleaned once a month using non 

aggressive detergents, either by hand or in the dishwasher, 
which must be set to a low temperature and a short cycle.  
When washed in a dishwasher, the grease filter may discolor 
slightly, but this does not affect its filtering capacity. 
To remove the grease filter, pull the spring release handle. 

 

Charcoal filter (filter version only) 

It absorbs unpleasant odors caused by cooking. 

The saturation of the 

charcoal filter

 occurs after more or less 

prolonged use, depending on the type of cooking and the 
regularity of cleaning of the grease filter. 
In any case it is necessary to replace the cartridge at least 
every four months. 
The charcoal filter may NOT be washed or regenerated. 
 

Fig. 12 

 

Replacing lamps 

The hood is equipped with a lighting system based on LED 
technology. 
The LEDs guarantee an optimum lighting, a duration up to 10 
times as long as the traditional lamps and allow to save 90% 
electrical energy. 
 
For replacement, contact the technical service. 
  
  
 
 

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Elica Elite 35 Grix/A/90?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"