It is necessary to drain off a small amount of water regularly (at least once a month) through 
the drain pipe of the safety valve into the sewage system to remove calcareous sediments and 
to test the valve's performance.

The handle (

6

) is designed to open the valve (

5

). Ensure that during operation of the water heater this 

handle is in such a position as to stop draining of water from the tank.

Connection to the water supply system is made in accordance with (

Fig.1

) with the help of copper, 

plastic pipes or special flexible flow pipes designed for temperatures of up to 100 °C at the maximum 
operating pressure. It is prohibited to use flexible pipes previously used. Plumbing and valves must 
comply with the parameters of the water supply network and have the necessary quality certificates. 
When installing, do not use excessive force to avoid damage to the threads of the tank nipples.

After connecting the EWH, make sure that the cold water shutoff valve (

15

) is open and the hot water 

shutoff valve (

14

) is closed. Open the valve of cold water supply to the EWH (

10

), the hot water outlet 

valve (

11

) and the hot water tap on the mixer to ensure air outflow from the EWH. At final filling of the 

EWH, a continuous stream of water will flow from the tap of the mixer. Close the hot water tap on the 
mixer, check the flange for leaks and, if necessary, tighten the bolts.

Drops of condensate appearing on the metal parts (nipples, case) associated with the temperature 
drop are not a drawback or leakage of the EWH itself.

When connecting the EWH in places not equipped with running water, it is allowed to supply water to 
the EWH from the storage tank using a pumping station, or from a container placed at a height of at 
least 5 meters from the top of the EWH.

Electrical installation

Before  switching  on  the  heater,  make  sure  that  its  parameters  correspond  to  the  technical 
specifications of the water heater.

WARNING! Before switching on the power supply, make sure that the EWH is filled with 
water!

The water heater must be grounded to ensure its safe operation. The water heater is equipped 
with a standard power supply cord with europlug and RCD (optional). The electrical socket 
should have a ground terminal with connected ground wire and be located in a place protected 
from moisture, or meet the requirements not lower than IPX4.

Operation and maintenance

During the operation of the EWH, the customer can adjust the temperature of the water heating in the 
EWH using the temperature control knob located on the protective cover of the EWH (

Fig. 1, item 17

). 

When the knob is turned counterclockwise to the stop, the EWH disconnects from the mains, when 
the knob is turned clockwise, the temperature gradually increases up to +74 °C (±5 °C).

If the water temperature exceeds +95 °C, the temperature switch trips, immediately disconnecting the 
tubular heater. To return the device to operating condition, it is necessary to press the button of the 
thermal switch (

Fig. 2

), which is located under the cover of the EWH, until it clicks.

Maintenance

During maintenance, the tubular heater should be inspected for scale. Simultaneously, a sediment, 
which can built up at the bottom of the EWH, should be removed. If there is a scale on the tubular 
heater, it can be removed with the help of special cleaning agents, or mechanically. It is necessary to 

18

carry out the first maintenance service a year after connection of the EWH and to determine the time 
frame of subsequent maintenance according to the intensity of the scale and sediment buildup. This 
will maximize the service life of the EWH.

WARNING: scale buildup can cause damage to the tubular heater.

Note:  Damage  to  the  tubular  heater  due  to  the  formation  of  scale  is  not  covered  by  the  warranty. 
Regular maintenance is not included in the manufacturer's and seller's warranty.

To carry out maintenance, it is necessary to do the following:

disconnect the EWH;

џ

let the hot water cool down or use it up through the mixer;

џ

shut off the cold water supply to the EWH;

џ

unscrew the safety valve or open the drain valve;

џ

put the rubber hose on the cold water supply nipple or the drain valve by directing the second end of 

џ

the hose into the sewer;
open the hot water tap on the mixer and drain the water from the EWH through the hose into the 

џ

sewer;
remove the protective cover, disconnect the wires, unscrew and remove the support flange from the 

џ

case;
descale the tubular heater if necessary and remove the sediment from the tank;

џ

assemble, fill the EWH with water and switch on the power.

џ

when  performing  technical  maintenance  of  the  EWH  by  a  specialized  organization,  a 

џ

corresponding note must be made on the warranty card.

Possible malfunctions and methods of their elimination

In case of a malfunction in the work of the product, disconnect it from the electrical network, shut off 
the water.

Remove the removable flange 
from the EWH and carefully 
clean/descale the tube

The thermostat tube is scaled up

Turn the thermostat knob 
towards decreasing the 
temperature (–)

The set temperature is close 
to the limit

Frequent actuation of the 
temperature switch

Possible cause

Solution

Voltage in the mains decreased

Contact the utility

Remove the flange and 
descale the heater

Tubular heater is scaled up

Heating time increased

Remove the valve and rinse 
it in water

Clogging of the inlet of the safety 
valve

Malfunction

Hot water pressure from 
the EWH decreased. 
Cold water pressure is 
the same.

19

EN

EN

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Thermex N 10 O/U?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"