If there is scale on TEH, then it can be removed by using scale removing means or mechanically. 
When removing residuals from EWH do not apply excessive force and do not use abrasive cleaners 
not to damage the protective coating of the inner tank.
 
Importance  of  the  first  maintenance  is  that  by  intensity  of  scale  and  residues,  magnesium  anode 
consumption terms for next maintenance services can be decided and, consequently, service life can 
be  extended.  In  case  of  non-observance  of  the  above  requirements  EWH  service  life  reduces, 
increases the probability of EWH breakdown and validity of warranty expires.
To perform maintenance and replace magnesium anode follow steps:
Turn off EWH power.
џ
Cool hot water or discharge it through the mixer.
џ
Cut off supply of cold water into EWH.
џ
Put a rubber hose on the cold water supply inlet pipe or discharge valve and direct the second end to
џ
the drain. 
Unscrew the relief valve or open drain valve. 
џ
Open a hot water faucet on the mixer.
џ
Drain water from the EWH through cold water supply inlet pipe or discharge valve.
џ
Remove the protective cover, disconnect wires, unscrew and remove from the casing the
џ
removable flange. 
Replace the magnesium anode, clean the TEH if necessary from scale and remove residue. 
џ
To assemble, fill EWH with water and power on.
џ
When conducting EWH maintenance by forces of special organization the appropriate mark shall be 
made in the warranty card. When replacing the magnesium anode independently by the consumer 
magnesium anode purchase receipt shall be attached to present manual.
Specifying security measures
Electrical safety and corrosion protection of EWH are guaranteed only if there is an effective 
earthing in accordance with applicable electric installation rules and regulations.
When installing and operating EWH the following is not allowed:
To power EWH if EWH is not filled with water.
џ
To remove the protective cover when the power is on.
џ
Use EWH without grounding or use water pipes as grounding.
џ
To connect EWH to water supply with pressure exceeding 0,6 MPa. (If pressure in the supply
џ
line is more than 0.6 MPa, an appropriate pressure reducing valve shall be installed at cold 
water  inlet  ahead  of  safety  valve  (not  supplied)  to  reduce  water  pressure  to  normal). 
Installation of pressure reducing valve between EWH and relief valve is forbidden. 
To connect EWH to the water supply without safety valve. 
џ
To drain water from EWH with power switched on.
џ
To use spare parts not recommended by the manufacturer.
џ
To use water from the EWH for cooking.
џ
To use water containing impurities (sand, small stones), which might lead to EWH and
џ
safety valve breakdown. 
To modify design and installation dimensions of EWH brackets. 
џ
EN
EN
 Water freezing in the appliance is prohibited because it causes its malfunction which is not a warranty 
case.
 
EWH is not intended to be used by persons with limitations of health, sense or mental limitations, as 
well as persons who are not able to use the EWH, except when it happens under the supervision or 
instructions  by  a  person  responsible  for  EWH  safety.  Children  can  use  EWH  only  under  the 
supervision  of  persons  who  know  how  to  operate  it  safely.  During  EWH  operation,  it  must  be 
inspected regularly for proper health (absence of dripping, burning smell, wiring sparks, etc.). In the 
case of long interruptions in water heater operation, water supply failures, EWH must be disabled and 
cold water inlet valve must be shut off.
Always be aware that there is a risk of hot water scalding and electric shock.
Possible faults and remedies
If an operational fault occurs EWH shall be disconnected from the mains, water supply shall be cut off.
Apply to a Service center.
Thermal switch tripped or 
not on.
Powered EWH does 
not heat water. 
No backlights 
of indicator lamps. 
Disconnect EWH from the mains, 
remove EWH protective cover, 
press the safety button until you 
hear a click (
fig. 3
), place the
cover and turn on power.
Power cord is damaged.
There is no voltage in the 
mains
Contact power supply operation 
service 
RCD (if any) tripped
Push RCD restart button. 
Check voltage. 
Frequent tripping of 
thermal switch
The set temperature is close 
to the limit
Turn the thermostat control to 
decrease temperature (
–
)
Thermostat tube is covered 
with sludge 
Remove the flange and gently 
clean the pipe from the sludge 
Heating time increased
THE is covered with a layer 
of sludge 
Remove the flange and clean 
the TEH 
Supply voltage decreased
Contact power main operation 
service 
Fault
Hot water pressure 
from EWH decreased. 
Cold water pressure 
keeps at the level. 
How to fix
Remove the valve and clean it 
in water
Possible cause
Clogged inlet safety valve
22
23

 
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
 