In case of emergencies use troubleshooting methods, listed in Table 2. 
If it is impossible to remedy problems by the listed methods, contact the 
manufacturer’s service center.

11. TROUBLESHOOTING

10. TRANSPORTATION AND STORAGE

1. When transporting, any possible impacts and movements of the 
package inside a vehicle must be avoided.

2. Handling symbols on the unit’s package must be strictly observed when 
transporting and storing it.

3.

Temperature 

requirements*

Humidity 

requirements*

Transportation and 

storage

-30°C to +50°C

15% to 85%
(no condensate)

We are researching new technologies and constantly improving the quality 
of our products. Specifications, design and scope of delivery may be 
changed without any prior notice.

* Products must be stored in dry, ventilated storages at the temperature not lower than -30°C.

Tabla

Problem

Possible cause

Remedy

Poor atomizing (insufficient capacity)

The unit is operating in the minimized 
mode (low atomizing frequency)

There is no problem. If you need 
to switch to the intensive mode of 
operation, press button «Set» and 
select the necessary steam outflow 
intensity.

The atomizer is clogged

Clean the atomizer.

Temperature of water in the tank 
is too low

Set maximum capacity. The 
humidifier’s capacity will go up after 
a while.

No atomizing

The power cord is poorly connected 
to the outlet

Connect the power cord into the 
outlet carefully

The humidifier’s life is 2 years. At the end of life, the humidifier must be 
disposed in accordance with regulations, rules and method, effective in 
the disposal area.

12

. UTILIZATIONE

Problem

Possible cause

Remedy

No atomizing

The red water level indicator is on 
(water in the tank is completely 
used up)

Add water into the tank

There is white deposit on objects 
around the humidifier (salts, 
separating out from water)

Lime deposits have formed on the 
membrane

Clean the humidifier’s membrane with 
a special brush

Properties of the water softening filter 
have deteriorated

Replace the water softening filter.

The water used contains large 
amounts of calcium and magnesium

Use softened water from a domestic 
filter

Difference between the current 
humidity level and hygrometer 
readings is too big

Dirt has accumulated inside the 
air vent

Clean the air vent.
Humidity may vary even in one room 
depending on the unit’s location and 
temperature

The unit operates in places with 
environmental exposure, for example, 
it is located by a window

Install the unit in places with no 
environmental exposure

Steam has an unpleasant odor

Stale water is used

Clean the unit according to the 
cleaning and maintenance instructions 
and fill the tank with fresh water

Remains of stale water or waste have 
accumulated in the unit’s case or 
the atomizer

Condensate is formed on the 
upper part of the humidifier and 
on surrounding objects, when it is 
operating.

1. High humidification intensity is set.
2. High room humidity and 
temperature.

Lower the humidification intensity with 
the help of the Set button.

Water appears next to the humidifier, 
when it is operating.

1. High humidification intensity is set.
2. The water tank is loosely installed 
on the unit’s base and there is a gap 
between them.
3. Lime deposits have formed on the 
membrane and in grooves for water 
(in the unit’s base).

1. Lower the humidification intensity 
with the help of the Set button.
2. Turn on the unit and make sure the 
water tank is installed correctly and 
without any gaps with respect to the 
unit’s base.
3. Clean the unit according to 
the cleaning and maintenance 
instructions.

Water appears next to the humidifier, 
when it is not operating.

The water tank is not leak proof.

Contact the manufacturer’s authorized 
service center.

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Timberk THU UL 17?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"