Timberk THU UL 11 - Инструкция по эксплуатации - Страница 6

Увлажнители Timberk THU UL 11 - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Если остались вопросы, задайте их в комментариях после инструкции.

"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.
Страница:
/ 28
Загружаем инструкцию
background image

www.timberk.com • 

electric humidifier

6

7. OPERATION OF THE UNIT

Connect the unit to the power line, having filled the tank with water first.
Press the on/off button, (the unit will automatically start operating), and the 

current air humidity will show up on the display.
At the very beginning of operation, the atomizing level may appear 

unstable, which is caused by the temperature difference and water quality. 

It takes some time for water to start turning into steam on the ultrasonic 

membrane. After 10-25 minutes the atomizing level will gradually stabilize.
To select the required room humidity, press the humidity level setting button 

(5). The unit will automatically adjust the steam outflow intensity to reach 

the humidity level you have set.
To adjust the humidity level manually, press button (2), the steam outflow 

intensity will change (low, medium, high). This action will be shown on the 

display by indicators.
The display show the set humidity level and the current humidity level after 

the user finishes setting up. The display show the actual room temperature.
By pressing the timer set button (4), you can set the time for the unit to 

switch off in 1 – 12 hours.
To activate air ionizing, press the corresponding button (3).
The ionizer generates negative ions (anions) and refreshes the room air. 

Anions reinforce the nervous and the blood-vascular system, improve lungs 

performance and provide effective protection against respiratory illnesses 

(such as asthma and pneumonia). Anions clean air from dust and smoke.
Press the warm steam on/off button (6) to humidify by warm steam. When 

humidifying by warm steam, water heating is performed by means of the 

built-in heater. Water in the tank is heated and fed through the atomizer 

turning into warm steam. The unit’s efficiency improves thanks to the 

combined humidification (cold and warm steam).

It will take about ten-twenty minutes to atomize warm steam (time required 

for water to be heating by the heater after it is switched on). The average 

warm steam temperature is 40°. Sometimes it is hard to feel the steam 

temperature due to the temperature difference and ambient humidity.
To deactivate the warm steam function, press button (6) again.
To switch off the unit, press the on/off button.

NOTE! 

It the warm steam function was activated when the unit 

was operating, then after the unit is switched off, the 

fan will keep on working for 5 minutes to cool down the 

heating element.

NOTE! 

Dear customer,
When using the humidifier, you may come across 

condensate generation on its upper part and objects 

next to it, including water accumulation, which is not a 

defect, but a feature of its operation. This feature may 

have several causes, listed in the table on page 14.

8. WATER SOFTENING FILTER CARTRIDGE

The unit’s scope of delivery includes 1 filter cartridge with balls out of mineral 

stone, installed on the water tank cap with the valve, 1 carbone filter (in set) 

and 1 ion resin filter (in set). Filter cartridge with balls out of mineral stone, 

which features strong absorbing properties. The filter absorbs elements of 

heavy metals such as lead, chrome, mercury, zinc, etc. It decontaminates 

water and restores normal pH level.
Filter’s life is 4-6 months, depending on the quality of water used and how 

often the unit is used.
If the white deposit appears on things around the humidifier when it is used, 

it may have the following causes:
1. Water used contains high amount of magnesium or calcium. You should 

use water that was preliminarily treated by a domestic water filter.
2. Residues of calcium and magnesium salts have accumulated inside the 

unit. You should clean inner parts of the unit.
3. Steam deposits suspended dust on a surface, contained in the air.
4. The water softening filter properties have deteriorated. You should 

replace the water softening filter.

Полезные видео

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Timberk THU UL 11?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"