Automatic Voltage Regulator
5. INSTALLATION AND OPERATION GUIDE
Attention! Before connecting the regulator, make sure that all con-
suming devices connected to it are off, and stabilizer switch is set
to “OFF” position.
Attention! When choosing an AVR, it is necessary to consider that
reduction of input voltage increases value of input current, which
means that maximum power of AVR is reduced too!
•
Before installing the AVR, please make sure that total power of all
consumers is lower than AVR power. Besides, take into account
the starting load and power factor of consumers, it is necessary
to apply power margin factor of 1.2–1.5; it should be 1.5–2 for such
equipment as air conditioners, fridges, etc
•
Connect the necessary equipment to the power outlet (s) of the sta
-
bilizer.
•
Connect the regulator to the power network of 230 V.
•
Turn on the stabilizer. When the built-in LED lights up the key, and LED light up: for a short
period to test, “Regulating” and “Delaying/Protection”, constantly, “Working”.
•
When the self-test is complete LED “Delaying/Protection” will go out and voltage connection
to the output receptacles will happen. If the LED “Delaying/Protection” at the end of the test
did not go out, it is prohibited to operate the regulator to eliminate the problem.
•
“Regulating” LED will light when the regulator to increase or decrease in the input voltage.
•
In case of overload or short circuit the thermal fuse is ready installed on the rear wall is trig
-
gered. Turn on the stabilizer after removing the cause of the overload by pressing the power
button.
•
When voltage input is more than 285 V or below 184 V regulator will disconnect the load. “De
-
laying/Protection” LED will light up.
•
“Delaying/Protection” indicator will light up in case of overheating auto-transformer, protec
-
tion will work. The load deenergises. After cooling down auto-transformer load power is re-
stored automatically.