Пылесос Bosch BGL 3CARP - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

46
Figure
●
Open the dust bag compartment lid.
●
Unlock the Hepa* filter by moving the locking tab in
the direction of the arrow, and remove it from the
appliance.
●
Tap out the filter unit and rinse it under running
water.
Alternatively, the unit can be cleaned in a washing
machine at max. 30 °C using a gentle programme and
the lowest spin speed.
TIP: To protect other laundry items, put the filter unit
into a laundry bag.
●
Once the Hepa* filter has dried completely (at least
24 hours), insert it back into the appliance and lock it
in place.
●
Close the rear flap.
After vacuuming fine dust particles (e.g. gypsum, ce-
ment, etc.), clean the motor protection filter by tapping
it out or, if necessary, replace the motor protection
filterand exhaust filter.
Care
Always switch off the vacuum cleaner and disconnect it
from the mains before cleaning the vacuum cleaner. The
vacuum cleaner and plastic accessories can be cleaned
with ordinary plastic cleaner.
!
Do not use abrasive materials, glass-cleaning
agentsor all-purpose cleaning products. Never
immerse the vacuum cleaner in water.
If required, the dust compartment can be vacuumed out
with a second vacuum cleaner or simply with a dry
duster/ dusting brush.
Subject to technical modifications.
26*
Figure
Opening the lid
a)
Unlock the lid by pulling on the locking lever in the
direction of the arrow.
b)
Open the lid in the direction of the arrow.
Figure
a)
Close the dust bag by pulling on the locking tab.
b)
Take out the dust bag.
c)
Insert a new dust bag.
d)
Push the dust bag fully into the holder.
!
Please note:
the lid will only close if a dust bag has
been inserted.
Replacing the exhaust filter
Vacuum cleaner with micro-hygiene filter
This should be replaced with every replacement filter
pack
Figure
●
Open the dust bag compartment lid.
Figure
a)
Release the filter holder by moving the locking lever
in the direction of the arrow.
b)
Remove the micro-hygiene filter.
c)
The micro-hygiene filter can be rinsed out.
●
The filter must then be left to dry for at least 24
hours.
d)
Remove the micro-hygiene filter. Insert the new
micro-hygiene filter into the appliance.
e)
Insert the filter holder into the appliance and lock it
in place.
Cleaning the Hepa* exhaust filter
The Hepa* filter is designed so that it does not need to
be replaced, provided the appliance is used as intended
in the household.
To ensure that the vacuum cleaner is working at its
optimum power level, the Hepa* filter should be rinsed
out after one year. The filtering action of the filter
remains intact, even if the filter surface becomes
discoloured.
25*
23
24
23
*depending on model












