Обогреватели Hyundai H-HV5-20-UI611 - инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.
Если остались вопросы, задайте их в комментариях после инструкции.
"Загружаем инструкцию", означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

11.
Electric convector
EN
SMT mode
Press button, symbol lights, Set required temperature and compared it with room
temperature, if setting temperature and room temperature diference is 5 degrees or over 5
degrees, the product works with high power (2000W), if setting temperature and room tempera-
ture diference is over 3 degrees but not more than 5 degrees, the product works with middle
power (1200W), if setting temperature and room temperature diference is less 3 degrees, the
product works with low power (800W), if setting temperature is higher than room temperature,
the product stops heating.
Power adjustment
Low power lights, of;
Middle power, lights, of;
High power, both on.
Protection function
Sensor problem protection: Sensor of or other problem, LED shows E1, heating element stops
heating output Tip-over protection: the products tip-over 45 degrees, it stops working, lash
-
es, and the product would be under standby status.
Over-heating protection: once the whole product is overheating, thermal limiter works, the prod-
uct would be power of, LED of.
Operation voice
When valid operate any button once, buzzer ring once, ater connection of power, buzzer ring
once.
Screen fade out Function
If no pressing of « » button together, all the symbols on LED would be on status.
Press « » button together, shows status of the product, other symbols of, press
any button to show working status.
Mandatory power functions
Within 2 minutes ater power on of the product for the irst time, SMART mode and temperature
setting function invalid, the whole product works under setting power for PCB checking of pro-
duction line.
Memory function
Thermo-limiter of and rework, tip-over switch rework and accidently electricity of, the product
will memory working status of last time.
SMT