GB

- 20 -

5.  Before starting the equipment

Before you connect the equipment to the mains 

supply make sure that the data on the rating plate 

are identical to the mains data.

5.1 Installation

The equipment can be installed either:

• 

 Stationary with a rigid pipe line

or

• 

 Stationary with a flexible hose line

The equipment must be fastened to the suspensi-

on eyelet with a rope (Fig. 2/Item 6).

The maximum pumping rate is possible only with 

the largest possible line diameter; if smaller hoses 

or pipes are connected, the pumping rate will be 

reduced. If the universal hose connection (Fig. 1/

Item 1) is used, it should be shortened (as shown 

in Fig. 9) to the connection actually used in order 

not to reduce the pumping rate unnecessarily. 

Flexible hoses must be fastened to the universal 

hose connection with a hose clip (not included in 

the scope of supply).

Note!

When installing, never hang the equipment by 

the discharge line or by the power cable. The 

equipment must be hung up by the provided carry 

handle or suspension eyelet, or it must rest on the 

bottom of the shaft. To ensure that the equipment 

works properly, the bottom of the shaft always 

must be free of sludge and other accumulations 

of dirt. If the water level is too low, the sludge 

in the shaft can quickly dry out and hinder the 

equipment from starting. It is necessary therefore 

to check the equipment regularly (carry out trial 

start-ups).

The pump shaft should measure at least 50 x 50 x 

50 cm so that the 

fl

 oating switch can move freely.

5.2 Mains connection

Danger!

The equipment you have purchased comes with 

an earthing-pin plug. The equipment is designed 

for connection to a socket outlet with earthing 

contact for 230 V ~ 50 Hz. Make sure that the 

socket-outlet is su

  ciently fused (at least 6 A) 

and in good working order. Insert the power plug 

in the socket-outlet and the equipment is ready 

for operation.

Danger!

To rule out danger, this work must be left strictly to 

a specialist electrician or Customer Service.

6. Operation

 You can put the equipment into operation after 

you have thoroughly read the installation and ope-

rating instructions. Pay attention to the following 

points:

• 

 Make sure that the equipment is set up secu-

rely.

• 

 Check that the discharge line is fitted correct-

ly.

• 

 Make sure that the electrical connection is 

230 V ~ 50 Hz.

• 

 Check that the electrical socket-outlet is in 

good working order.

• 

 Make sure that no moisture or water can ever 

reach the power connection.

• 

 Make sure that the equipment does not run 

dry.

• 

 To switch off the equipment, pull the power 

plug out of the socket outlet.

 Setting the On/O

  switching point:

The ON/OFF switching point can be in

fi

 nitely ad-

justed with the height adjustment facility. For this 

purpose you must 

fi

 rst slacken the screw (Fig. 3, 

Item 3). The switching di

 erential can be in

fi

 nitely 

adjusted by extending or shortening the 

fl

 oat 

cable (Fig. 3).

• 

 The floating switch must be fitted so that the 

switching point height: ON and the switch 

point height: OFF can be reached easily and 

with little force. Check this by placing the 

equipment in a container filled with water 

and carefully raising and lowering the floating 

switch with your hand. You can then see whe-

ther the equipment switches on and off.

• 

 Make sure that the distance between the floa-

ting switch head and the cable holder is not 

too smaller than 10 cm (Fig. 3). If the distance 

is too small, there is no guarantee that the 

equipment will work correctly.

• 

 When adjusting the floating switch, make 

sure that the floating switch does not touch 

the bottom before the equipment is switched 

off. Important! Risk of dry running.

Anl_GE_DP_7330LL_5220LL_SPK7.indb   20

Anl_GE_DP_7330LL_5220LL_SPK7.indb   20

23.07.15   11:19

23.07.15   11:19

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к Einhell GE-DP 5220 LL?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"