Before calling for service, review this list. It may save you time and expense. This
list includes common occurrences that are not the result of defective workman-
ship or materials in this appliance.
PROBLEM
sOLUTION
Air conditioner
does not start
Wall plug disconnected. Push plug firmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse
with time delay type or reset circuit breaker.
selector Control in OFF position. Turn selector to the desired
FAN or COOL setting.
Unit turned off by moving thermostat to a higher number
and then immediately turning back to a colder number.
Wait approximately 3 minutes. Listen for compressor to start.
Unit turned off and then on too quickly. Turn unit off and
wait 3 minutes before restarting.
Thermostat set too low. Adjust thermostat to higher number
for cooling.
Air from unit does
not feel cold
enough
Turn selector to a higher COOL position.
Thermostat set too warm. set thermostat to colder tempera
-
ture.
Room temperature below 18 C(64 F). Cooling may not oc
-
cur until room temperature O Orises above 18 C(64 F).
Temperature sensing tube touching cold coil, located be
-
hind air filter. straighten tube away from coil.
Air conditioner
cooling, but room
is too warm- ice
forming on cooling
coil behind deco
-
rative front.
Outdoor temperature below 18 C(64 F). To defrost the coil,
set selector to FAN position. Then, set thermostat to warmer
position.
Air filter may be dirty. Clean filter. Refer to Care and Clean
-
ing section. To defrost, set selector to FAN.
Thermostat set too cold for night-time cooling. To defrost
the coil, set selector to a FAN position. Then, set thermostat
to a warmer position.
Noise when unit is
cooling
Air movement sound. This is normal . If too loud, turn selector
to lower FAN setting.
sound of fan hitting water-moisture removal system. This is
normal when humidity is high.
Close doors, windows and registers.
Window vibration - poor installation. Refer to installation
instructions or check with installer.
TROublEshOOTING