Back-UPS Pro BR650MI / BR900MI / BR1300MI / BR1600MI

6

Alerts and System Errors

Audible indicators

Alert icons

Mute: 

If the line through the speaker icon is illuminated, the audible alarm has 

been turned off.

Replace Battery: 

The battery is nearing the end of its useful life. Replace the 

battery as early as possible.

On Battery: 

The Back-UPS is supplying battery backup power to the 

connected equipment, it will beep four times every 30 seconds.

Four Beeps Every 30 Seconds

Back-UPS is running on battery. You should consider saving 

any work in progress.

Continuous Beeping 

Low battery condition and battery run-time is very low. 

Promptly save any work in progress, exit all open 

applications, and shut down the operating system.

Continuous tone

Battery Backup outputs are overloaded. 

Chirps every 2 Seconds with the Load 

Capacity Bar flashing

Battery is disconnected. 

Continuous chirping with the Load 

Capacity Bar and Replace Battery icon 

alternately flashing

Battery did not pass the automatic diagnostic test and should 

be replaced as early as possible. Pressing the 

MUTE 

button 

pauses the chirping.

If these icons are 

illuminated...

This may be the problem.

The Back-UPS is operating on AC power, but is overloaded. Disconnect one 

of the items connected to the Back-UPS. If the Overload icon stops flashing, 

the Back-UPS is no longer overloaded and will continue to operate 

normally.
The Back-UPS is operating on battery power, but is overloaded. Disconnect 

one of the items connected to the Back-UPS. If the Overload icon stops 

flashing, the Back-UPS is no longer overloaded and will continue to operate 

normally.

The Back-UPS is operating on AC power, but the battery is not functioning 

properly. Contact Schneider Electric IT (SEIT) Customer Service to order a 

replacement battery. See 

“Battery Replacement” on page 11

.

The Back-UPS is operating on battery power and the battery power is 

getting low. Shut down all connected equipment to avoid losing an unsaved 

data. When possible, connect the Back-UPS to AC power to recharge the 

battery.

Характеристики

Оцените статью
tehnopanorama.ru
Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Задать вопрос

Часто задаваемые вопросы
Как посмотреть инструкцию к APC 650?
Необходимо подождать полной загрузки инструкции в сером окне на данной странице
Руководство на русском языке?
Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью
Как скопировать текст из PDF?
Чтобы скопировать текст со страницы инструкции воспользуйтесь вкладкой "HTML"